PROMED P50

Capacity: 20 Kg/hour (44 Lbs/H)
Usage Area: Clinics and Small-Scale Hospitals

  • Pressure chamber made of durable and high-quality stainless steel
  • Certified design and production approved by TÜV Austria
  • Manufactured in compliance with EU Directives PED (2014/68/EU), 2006/42/EC, 2014/30/EU, EN285, and EU Standards
  • Advanced automation control system enhanced with reporting and visualization software
  • Online access for remote monitoring and fault diagnosis
  • Fully automated operation with no need for operator intervention
  • Automatic loading elevator for user convenience
  • Innovative design with zero water consumption
  • Integrated steam boilers equipped with a state-of-the-art steam regeneration system for low fuel and electricity consumption
Tıbbi Atık Sterilizasyon Cihazları
Tıbbi Atık Sterilizasyon Cihazları
Tıbbi Atık Sterilizasyon Cihazları

Sterilization Cycle

Tıbbi Atık Sterilizasyon

When the sterilization cycle begins, the top lid automatically opens, and the waste is emptied from the discharge chamber into the device. Once the waste is fully transferred, the lid closes, and the shredding process starts.

The PLC-controlled shredding mechanism automatically adjusts its rotation direction with the “anti-blockage” system, preventing blade jamming.

The specially developed shredding system can efficiently process stainless steel surgical instruments and durable ceramic materials.

The mixer located in the upper chamber continuously feeds material into the shredding unit, ensuring a seamless and efficient operation.

Tıbbi Atık Sterilizasyon
Tıbbi Atık Sterilizasyon

Steam is supplied to the device until a uniform temperature of 134°C (274°F) is reached in both the upper and lower chambers. Sterilization is completed by maintaining the temperature between 134°C and 138°C with equivalent pressure for 10 minutes.

These processes ensure an 8Log10 reduction in the pathogenic contamination level of medical waste.

During the cooling process, excess steam accumulated in the chamber is discharged, while the temperature of the sterilized waste is lowered through cold air injection. The condensed water, which has undergone sterilization and can be safely released into the sewage system, is filtered and discharged using a pressure and vacuum system.

Tıbbi Atık Sterilizasyon
Tıbbi Atık Sterilizasyon

When the discharge lid opens, a container is positioned beneath the chamber, allowing the sterilized waste to be easily released. Once the container is removed, the bottom lid closes, and the sterilizer automatically initiates the next cycle.

Key Features

Technical Specifications Value
Dimensions (L x W x H) (mm) 2700 x 1500 x 1500
Weight (Kg) 2100
Steam Pressure (Bar max) 8
Required Electrical Power (Kw) 30*
Operating Features Value
Sterilization Capacity (Kg/Hour) 15-20
Processing Volume Capacity (Lt) 75
Average Waste Density (Kg/m3) 100-150
Average Cycle Time (Min) 30
Maximum Steam Flow (Kg/Hour) 100
Sterilization Efficiency (SAL) 8Log10
Consumption / Cycle Value
Steam (Kg) 6
Electricity (Kw) 1.2**
Water (Lt) None***
Special Consumables None
* P50 – P100 – P150 models include an internal steam boiler.
** Electricity consumption for the sterilizer only.
*** Water consumption of the integrated steam boiler: 7-12 Lt / Cycle